Clark Environmental, Inc.
Mulberry, Florida 33860
Local: 863-425-4884
Toll-Free: 800-276-2187
Fax: 863-425-2854

Ft. Pierce Office
4117 Bandy Boulevard
Ft. Pierce, FL 34981
772-464-4884
Fax: 772-464-5566
  62-713-Soil Thermal Treatment Facilities
Testing and Sampling Requirements




  1. Pre-Acceptance Testing Criteria-Two types

    1. For sites which have an approved site assessment report according to the requirements of Chapter 62-770 F.A.C., existing data from the site assessment may be used, if documented on form 62-713.900 (3) in lieu of separate pretreatment analysis including Arsenic, Cadmium, Chromium, or Lead.

    2. Thermal Treatment Testing

    l)Preburns-Virgin
    Test Method
    >= Must Run TCLP
    A) Volatile Organic Halocarbons
    8260B, 8021B

    B) TRPH
    FL-PRO

    C) Metals-Arsenic
    6010B, 7060A, 7061A, 6020
    100ppm
              Cadmium
    6010B, 7180, 7131A, 6020
    20ppm
              Chromium
    6010B, 7190, 7191, 6020
    100ppm
              Lead
    6010B, 7420, 7421, 6020
    100ppm
    ll) Preburns-Non-Virgin

    A) Volatile Organic Halocarbons
    8260B, 8021B

    B) TRPH
    FL-PRO

    C) Metals-Arsenic
    6010B, 7060A, 7061A, 6020
    100ppm
              Cadmium
    6010B, 7130, 7131A, 6020
    20ppm
              Chromium
    6010B, 7190, 7191, 6020
    100ppm
              Lead
    6010B, 7420, 7421, 6020
    100ppm
    D) PCB
    8082

    E) TOX
    9056, 9253

    lll) Coal Tar/Creosote

    A) Volatile Organic Halocarbons
    8260B, 8021B

    B) Semi-Volatile Organic Compounds
    8270C

    C) Metals-Arsenic
    6010B, 7060A, 7061A, 6020
    100ppm
              Barium
    6010B, 7080A, 7081, 6020
    2000ppm
              Cadmium
    6010B, 7130, 7131A, 6020
    20ppm
              Chromium
    6010B, 7190, 7191, 6020
    100ppm
              Lead
    6010B, 7420, 7421, 6020
    100ppm
              Mercury
    7471A, 7472
    4ppm
              Selenium
    6010B, 7740, 7741A, 6020, 7742
    20ppm
              Silver
    6010B, 7760A, 7761, 6020
    100ppm
    D) Cyanide
    9010B, 9012A, 9013, 9014, 9213



  2. Sampling-Number of samples required/site tonnage
TABLE A

Amount of Soil by Volume, yd3Amount of Soil by Weight, tonsNumber of discrete samples required for Volatile OrganicsNumber of Composite
Samples Required for Non-Volatile Organics
< 100< 14011
100 to < 500140 to <70033
500 to < 1000700 to < 140055
For each additional 500 yd3For each additional 700 tons11

Overview    |    Profile Document    |    Testing Requirements
Clean Fill    |    Permits    |    Photos    |    New Plant
   
2003-2009 Clark Environmental, Inc. All rights reserved. Please direct website issues to: webmaster@clarkenvironmental.com